In the Eurocode series of
European standards European Standards (abbreviated EN, from the German name ("European Norm")) are technical standards which have been ratified by one of the three European standards organizations: European Committee for Standardization (CEN), European Committee for ...
(EN) related to
construction Construction is a general term meaning the art and science to form objects, systems, or organizations,"Construction" def. 1.a. 1.b. and 1.c. ''Oxford English Dictionary'' Second Edition on CD-ROM (v. 4.0) Oxford University Press 2009 and com ...
, '' Eurocode 2: Design of concrete structures'' (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of
concrete Concrete is a composite material composed of fine and coarse aggregate bonded together with a fluid cement (cement paste) that hardens (cures) over time. Concrete is the second-most-used substance in the world after water, and is the most wi ...
,
reinforced concrete Reinforced concrete (RC), also called reinforced cement concrete (RCC) and ferroconcrete, is a composite material in which concrete's relatively low tensile strength and ductility are compensated for by the inclusion of reinforcement having hig ...
and
prestressed concrete Prestressed concrete is a form of concrete used in construction. It is substantially "prestressed" ( compressed) during production, in a manner that strengthens it against tensile forces which will exist when in service. Post-tensioned concreted i ...
structures, using the
limit state design Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria ...
philosophy. It was approved by the
European Committee for Standardization The European Committee for Standardization (CEN, french: Comité Européen de Normalisation) is a public standards organization whose mission is to foster the economy of the European Single Market and the wider European continent in global tr ...
(CEN) on 16 April 2004 to enable designers across Europe to practice in any country that adopts the code. Concrete is a very strong and economical material that performs exceedingly well under
compression Compression may refer to: Physical science *Compression (physics), size reduction due to forces *Compression member, a structural element such as a column *Compressibility, susceptibility to compression * Gas compression *Compression ratio, of a ...
. Its weakness lies in its capability to carry tension forces and thus has its limitations.
Steel Steel is an alloy made up of iron with added carbon to improve its strength and fracture resistance compared to other forms of iron. Many other elements may be present or added. Stainless steels that are corrosion- and oxidation-resistant ty ...
on the other hand is slightly different; it is similarly strong in both compression and tension. Combining these two materials means
engineer Engineers, as practitioners of engineering, are professionals who invent, design, analyze, build and test machines, complex systems, structures, gadgets and materials to fulfill functional objectives and requirements while considering the l ...
s would be able to work with a composite material that is capable of carrying both tension and compression forces. Eurocode 2 is intended to be used in conjunction with: *
EN 1990 En or EN may refer to: Businesses * Bouygues (stock symbol EN) * Esquimalt and Nanaimo Railway (reporting mark EN, but now known as Southern Railway of Vancouver Island) * Euronews, a news television and internet channel Language and writing * E ...
: Eurocode - Basis of structural design; *
EN 1991 In the Eurocode series of European standards (EN) related to construction, ''Eurocode 1: Actions on structures'' (abbreviated EN 1991 or, informally, EC 1) describes how to design load-bearing structures. It includes characteristic values for vari ...
: Eurocode 1 - Actions on structures; *hENs, ETAGs and ETAs: Construction products relevant for concrete structures; * ENV 13670: Execution of concrete structures; *
EN 1997 In the Eurocode series of European standards (EN) related to construction, ''Eurocode 7: Geotechnical design'' (abbreviated EN 1997 or, informally, EC 7) describes how to design geotechnical structures, using the limit state design philosophy. I ...
: Eurocode 7 - Geotechnical design; * EN 1998: Eurocode 8 - Design of structures for earthquake resistance, when concrete structures are built in seismic regions. Eurocode 2 is subdivided into the following parts:


Part 1-1: General rules, and rules for buildings

EN 1992-1-1 deals with the rules and concepts required for designing concrete, reinforced concrete and prestressed concrete structures. There are three main stages are involved in the design of elements in these structures: * Pre-design: Before any other designing is undertaken, the limit states of durability and fire design are considered in order to ascertain the required cover to the reinforcement, the minimum size of members and the appropriate concrete strength. * Ultimate limit state: Accurate section sizes are determined for corresponding concrete properties (usually compressive strength). The size of the reinforced concrete element and the quantity of reinforcement to resist bending, shear and torsional forces are determined. * Serviceability limit state. In this phase of the work, checks are made to ensure the serviceability criteria (i.e. that the building is comfortable to use) are met.


Pre-design

Pre-design stage involves selecting initial section sizes (e.g. reinforcement diameter), from which the minimum required cover depth could be selected to attain the required fire resistance. Although these initial estimates are likely to change throughout the design, giving considerable amount of thought at this stage is likely to save a lot of time later on.


Ultimate limit state

Ultimate limit states are often more critical for concrete structures. Consequently, when design is undertaken, the ultimate limit state is designed for and then if necessary serviceability is checked for. However, element sizes ascertained in the pre-design stage usually ensure serviceability criteria are met.


Serviceability limit state

Serviceability requirements to check for deflection and crack widths are generally satisfied by observing the following details. * Checking and keeping within permitted span/effective depth ratios * Providing not less than the minimum permitted percentage of reinforcement. * Limiting the spacing of tension reinforcement. * Using “deemed to satisfy” empirical methods. If actual deflections are required, then the structure must be analysed for the serviceability limit state, using design service loads. The deflections obtained will generally be short term values and will be multiplied by a suitable factor to allow for creep effects and to give realistic long term values.


Contents

* General * Basis of design * Materials (
concrete Concrete is a composite material composed of fine and coarse aggregate bonded together with a fluid cement (cement paste) that hardens (cures) over time. Concrete is the second-most-used substance in the world after water, and is the most wi ...
and
steel Steel is an alloy made up of iron with added carbon to improve its strength and fracture resistance compared to other forms of iron. Many other elements may be present or added. Stainless steels that are corrosion- and oxidation-resistant ty ...
) including **
Concrete Concrete is a composite material composed of fine and coarse aggregate bonded together with a fluid cement (cement paste) that hardens (cures) over time. Concrete is the second-most-used substance in the world after water, and is the most wi ...
** Reinforcing steel **
Prestressing Prestressed concrete is a form of concrete used in construction. It is substantially "prestressed" ( compressed) during production, in a manner that strengthens it against tensile forces which will exist when in service. Post-tensioned concreted i ...
steel * Durability and cover to reinforcement * Structural analysis * Ultimate
limit state Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria ...
s * Serviceability limit states * Detailing
reinforcement In behavioral psychology, reinforcement is a consequence applied that will strengthen an organism's future behavior whenever that behavior is preceded by a specific antecedent stimulus. This strengthening effect may be measured as a higher freq ...
and prestressing tendons * Detailing members, and particular rules * Precast elements - additional rules * Lightweight aggregated concrete structures * Plain and lightly reinforced concrete structures


Part 1-2: Structural fire design

EN 1992-1-2 deals with the design of concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1992-1-1 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design. Part 1-2 of EN 1992 deals only with passive methods of fire protection. Active methods are not covered.


Part 1-3: Precast Concrete Elements and Structures

EN 1992-1-3 gives a general basis for the design and detailing of concrete structures in buildings made partly or entirely of
precast Precast concrete is a construction product produced by casting concrete in a reusable mold or "form" which is then cured in a controlled environment, transported to the construction site and maneuvered into place; examples include precast beam ...
elements.


Part 1-4: Lightweight aggregate concrete with closed structure

EN 1992-1-4 gives a general basis for the design of buildings and civil engineering works in reinforced and prestressed concrete made with lightweight aggregate concrete with closed structure.


Part 1-5: Structures with unbonded and external prestressing tendons

EN 1992-1-5 gives a general basis for the design of reinforced concrete components provided with unbonded tendons placed within or outside the concrete. In addition, it provides design rules which are mainly applicable to buildings but, does not apply to structures subjected to significant fatigue under variable loads. It does also not apply to structures with tendons temporarily ungrouted during construction.


Part 1-6: Plain concrete structures

EN 1992-1-6 provides supplementary rules to the general rules given in ENV 1992-1-1 for the design of components in building and civil engineering works in plain concrete made with normal weight aggregate.


Part 2: Reinforced and prestressed concrete bridges

EN 1992-2 gives a basis for the design of bridges in plain, reinforced and prestressed concrete made with normal and light weight aggregates.


Contents

* General * Basis of design * Materials * Durability and cover to reinforcement *
Structural analysis Structural analysis is a branch of Solid Mechanics which uses simplified models for solids like bars, beams and shells for engineering decision making. Its main objective is to determine the effect of loads on the physical structures and thei ...
* Ultimate
limit states Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria ...
* Serviceability limit states * Detailing of reinforcement and prestressing tendons - General * Detailing of members and particular rules * Additional rules for precast concrete elements and structures * Lightweight aggregate
concrete Concrete is a composite material composed of fine and coarse aggregate bonded together with a fluid cement (cement paste) that hardens (cures) over time. Concrete is the second-most-used substance in the world after water, and is the most wi ...
structures * Plain and lightly reinforced concrete structures * Design for the execution stages


Part 3: Liquid retaining and containing structures

EN 1992-3 complements EN 1992-1-1 for the particular aspects of liquid retaining structures and structures for the containment of granular solids.